Sources.MassFlowSource_T ​

Ideal fluid source with prescribed total mass flow, temperature, composition, and trace substances.

Positive prescribed mass flow leaves the source through its fluid ports. The mass flow may be supplied by a parameter or by a signal input.

This component extends from FluidComponents.Sources.BaseClasses.PartialFlowSource

Usage ​

FluidComponents.Sources.MassFlowSource_T(m_flow, T, X=MediaComponents.Interfaces.medium_X_default(medium_data), C=MediaComponents.Interfaces.medium_C_default(medium_data))

Parameters: ​

NameDescriptionUnitsDefault value
medium_data–
nPorts–
nX–FluidCompon...edium_data)
nXi–FluidCompon...edium_data)
nC–FluidCompon...edium_data)
use_m_flow_in–
m_flowkg/s
TK
Xkg/kgMediaCompon...edium_data)
C–MediaCompon...edium_data)

Connectors ​

  • ports - Generic fluid connector at the design outlet. (FluidPort_b)

  • m_flow_in - This connector represents a real signal as an input to a component (RealInput)

Variables ​

NameDescriptionUnits
m_flow_internalkg/s
port_m_flowskg/s

Behavior ​

This component has required parameters without default values, so it is not constructed here; see the Parameters table.

Source ​

dyad
"""
Ideal fluid source with prescribed total mass flow, temperature, composition,
and trace substances.

Positive prescribed mass flow leaves the source through its fluid ports. The
mass flow may be supplied by a parameter or by a signal input.
"""
component MassFlowSource_T
  extends FluidComponents.Sources.BaseClasses.PartialFlowSource(nPorts(min = 1))
  # Whether the mass flow is supplied through a signal input [-]
  structural parameter use_m_flow_in::Boolean
  # Fixed mass flow rate leaving the source [kg/s]
  parameter m_flow::MediaComponents.Types.MassFlowRate if !use_m_flow_in
  # Source temperature [K]
  parameter T::MediaComponents.Types.Temperature
  # Source mass fractions [kg/kg]
  parameter X::MediaComponents.Types.MassFraction[nX] = MediaComponents.Interfaces.medium_X_default(medium_data)
  # Source trace substances [-]
  parameter C::MediaComponents.Types.ExtraProperty[nC] = MediaComponents.Interfaces.medium_C_default(medium_data) if nC > 0
  "Prescribed mass-flow signal."
  m_flow_in = RealInput(units = "kg/s") if use_m_flow_in {
    "Dyad": {
      "placement": {
        "diagram": {"iconName": "default", "x1": -100, "y1": 0, "x2": 100, "y2": 200, "rot": 0},
        "icon": {"iconName": "default", "x1": -100, "y1": 0, "x2": 100, "y2": 200, "rot": 0}
      }
    }
  }
  # Effective prescribed mass flow rate [kg/s]
  variable m_flow_internal::MediaComponents.Types.MassFlowRate
  # Mass flow rate at each fluid port [kg/s]
  variable port_m_flows::MediaComponents.Types.MassFlowRate[nPorts]
relations
  if use_m_flow_in
    m_flow_internal = m_flow_in
  else
    m_flow_internal = m_flow
  end
  medium.T = T
  for i in 1:nPorts
    port_m_flows[i] = ports[i].m_flow
  end
  sum(port_m_flows) = -m_flow_internal
  if nXi > 0
    for j in 1:nXi
      medium.Xi[j] = X[j]
    end
  end
  if nC > 0
    for i in 1:nPorts
      for j in 1:nC
        ports[i].C_outflow[j] = C[j]
      end
    end
  end
metadata {
  "Dyad": {
    "labels": [{"label": "$(instance)", "x": 500, "y": 950, "rot": 0, "layer": "icon"}],
    "icons": {"default": "dyad://FluidComponents/icons/MassFlowSource_T.svg"}
  }
}
end
Flattened Source
dyad
"""
Ideal fluid source with prescribed total mass flow, temperature, composition,
and trace substances.

Positive prescribed mass flow leaves the source through its fluid ports. The
mass flow may be supplied by a parameter or by a signal input.
"""
component MassFlowSource_T
  # Immutable medium definition selected at model construction [-]
  structural parameter medium_data::MediaComponents.Interfaces.AbstractPartialMediumData
  # Number of fluid ports [-]
  structural parameter nPorts::Integer(min = 0)
  # Number of mass fractions [-]
  final structural parameter nX::Integer = MediaComponents.Interfaces.medium_nX(medium_data)
  # Number of independent mass fractions [-]
  final structural parameter nXi::Integer = MediaComponents.Interfaces.medium_nXi(medium_data)
  # Number of extra transported properties [-]
  final structural parameter nC::Integer = MediaComponents.Interfaces.medium_nC(medium_data)
  "Thermodynamic properties inside the source."
  medium = MediaComponents.Interfaces.BaseProperties(medium_data = medium_data)
  "Fluid ports connected to the source."
  ports = [FluidComponents.Interfaces.FluidPort_b(medium_data = medium_data) for i in 1:nPorts] {
    "Dyad": {
      "placement": {
        "diagram": {"iconName": "default", "x1": 950, "y1": 450, "x2": 1050, "y2": 550, "rot": 0},
        "icon": {"iconName": "default", "x1": 950, "y1": 450, "x2": 1050, "y2": 550, "rot": 0}
      }
    }
  }
  # Whether the mass flow is supplied through a signal input [-]
  structural parameter use_m_flow_in::Boolean
  # Fixed mass flow rate leaving the source [kg/s]
  parameter m_flow::MediaComponents.Types.MassFlowRate if !use_m_flow_in
  # Source temperature [K]
  parameter T::MediaComponents.Types.Temperature
  # Source mass fractions [kg/kg]
  parameter X::MediaComponents.Types.MassFraction[nX] = MediaComponents.Interfaces.medium_X_default(medium_data)
  # Source trace substances [-]
  parameter C::MediaComponents.Types.ExtraProperty[nC] = MediaComponents.Interfaces.medium_C_default(medium_data) if nC > 0
  "Prescribed mass-flow signal."
  m_flow_in = RealInput(units = "kg/s") if use_m_flow_in {
    "Dyad": {
      "placement": {
        "diagram": {"iconName": "default", "x1": -100, "y1": 0, "x2": 100, "y2": 200, "rot": 0},
        "icon": {"iconName": "default", "x1": -100, "y1": 0, "x2": 100, "y2": 200, "rot": 0}
      }
    }
  }
  # Effective prescribed mass flow rate [kg/s]
  variable m_flow_internal::MediaComponents.Types.MassFlowRate
  # Mass flow rate at each fluid port [kg/s]
  variable port_m_flows::MediaComponents.Types.MassFlowRate[nPorts]
relations
  for i in 1:nPorts
    ports[i].p = medium.p
    ports[i].h_outflow = medium.h
    if nXi > 0
      for j in 1:nXi
        ports[i].Xi_outflow[j] = medium.Xi[j]
      end
    else
      ports[i].Xi_outflow[1] = 0
    end
    if nC == 0
      ports[i].C_outflow[1] = 0
    end
  end
  if use_m_flow_in
    m_flow_internal = m_flow_in
  else
    m_flow_internal = m_flow
  end
  medium.T = T
  for i in 1:nPorts
    port_m_flows[i] = ports[i].m_flow
  end
  sum(port_m_flows) = -m_flow_internal
  if nXi > 0
    for j in 1:nXi
      medium.Xi[j] = X[j]
    end
  end
  if nC > 0
    for i in 1:nPorts
      for j in 1:nC
        ports[i].C_outflow[j] = C[j]
      end
    end
  end
metadata {
  "Dyad": {
    "labels": [{"label": "$(instance)", "x": 500, "y": 950, "rot": 0, "layer": "icon"}],
    "icons": {"default": "dyad://FluidComponents/icons/MassFlowSource_T.svg"}
  }
}
end


Test Cases ​

No test cases defined.

  • Examples

  • Experiments

  • Analyses