FluidComponents ​
This is the documentation for the FluidComponents library. Here you will find the documentation for the various definitions contained in FluidComponents.
Note that this documentation is automatically generated primarily from the doc strings and metadata associated with those definitions.
Types ​
Interfaces.PartialDistributedFlow- Base class for a distributed momentum balance.Interfaces.PartialDistributedVolume- Base class for a one-dimensional finite-volume discretization of fluid storage.Interfaces.PartialHeatTransfer- Common interface for heat transfer between distributed fluid segments andInterfaces.PartialStaggeredFlowModel- Base class for staggered-grid momentum balances between adjacent fluid states.Interfaces.PartialTwoPort- Partial interface for fluid components with two ports.Interfaces.PartialTwoPortTransport- Partial element transporting fluid between two ports without storing mass orPipes.BaseClasses.FlowModels.PartialStaggeredFlowModel- Base class for staggered-grid momentum balances between adjacent fluid states.Pipes.BaseClasses.HeatTransfer.PartialFlowHeatTransfer- Base class for heat-transfer correlations along a distributed fluid-flow path.Pipes.BaseClasses.PartialTwoPortFlow- Base class for distributed fluid flow with finite-volume storage and staggered momentum balances.Sources.BaseClasses.PartialFlowSource- Base class for prescribed fluid-flow sources with one or more fluid ports.Sources.BaseClasses.PartialSource- Base class for prescribed fluid boundaries with one or more fluid ports.Valves.BaseClasses.PartialValve- Base class for valves that transport fluid without storing mass or energy.Valves.BaseClasses.ValveCharacteristic- Inherent valve-flow characteristic selected for a valve model.
Connectors ​
Interfaces.FluidPort- Interface for quasi one-dimensional fluid flow in a piping network.Interfaces.FluidPort_a- Generic fluid connector at the design inlet.Interfaces.FluidPort_b- Generic fluid connector at the design outlet.
Components ​
Examples.BranchingDynamicPipes- Branching network of dynamic pipes with a pressure step at the upper boundary.Examples.HeatExchanger.BaseClasses.BasicHX- Two-stream heat exchanger composed of distributed fluid pipes and a separatingExamples.HeatExchanger.BaseClasses.WallConstProps- Pipe wall with lumped thermal capacitance, one-dimensional heat conduction,Examples.HeatExchanger.WaterToWaterCounterFlow- Transient counterflow heat exchanger with hot liquid water transferring heat toExamples.IncompressibleFluidNetwork- Multi-way network of eleven dynamic pipes, three incompressible valves, andPipes.BaseClasses.FlowModels.NominalLaminarFlow- Linear laminar flow model parameterized by nominal pressure loss and mass flow.Pipes.BaseClasses.HeatTransfer.ConstantFlowHeatTransfer- Distributed heat-transfer model with a constant heat-transfer coefficient.Pipes.DynamicPipe- Straight pipe with distributed storage of mass and energy and staggeredSources.Boundary_pT- Fluid boundary with prescribed pressure, temperature, composition, and traceSources.MassFlowSource_T- Ideal fluid source with prescribed total mass flow, temperature, composition,Tests.ValveIncompressibleVerification- Concrete verification network for the three operating modes ofValves.ValveIncompressible- Valve for liquids and other fluids whose density changes little across the
Analyses ​
Examples.BranchingDynamicPipesTransient- Transient pressure-step analysis of the branching dynamic-pipe network.Examples.HeatExchanger.WaterToWaterCounterFlowTransient- Transient analysis of hot water transferring heat to cold water.Examples.IncompressibleFluidNetworkTransient- Transient analysis of the incompressible multi-way pipe network.Tests.ValveIncompressibleVerificationTransient- Transient verification of the incompressible-valve operating modes.