FluxTubes.VariableReluctance
Variable reluctance This component is translated by DyadAI
This component extends from TwoPort
Usage
TranslatedComponents.FluxTubes.VariableReluctance()
Connectors
port_p- (MagneticPort)port_n- (MagneticPort)R_m- This connector represents a real signal as an input to a component (RealInput)
Variables
| Name | Description | Units |
|---|---|---|
V_m | Magnetic potential difference of ports | A |
Phi | Magnetic flux from port_p to port_n | Wb |
Behavior
Source
dyad
# Variable reluctance
# This component is translated by DyadAI
component VariableReluctance
extends TwoPort
R_m = RealInput()
relations
V_m = Phi * R_m
endFlattened Source
dyad
# Variable reluctance
# This component is translated by DyadAI
component VariableReluctance
port_p = MagneticPort()
port_n = MagneticPort()
# Magnetic potential difference of ports
variable V_m::Dyad.MagneticPotentialDifference
# Magnetic flux from port_p to port_n
variable Phi::Dyad.MagneticFlux
R_m = RealInput()
relations
V_m = port_p.V_m - port_n.V_m
Phi = port_p.Phi
0 = port_p.Phi + port_n.Phi
V_m = Phi * R_m
metadata {}
endTest Cases
No test cases defined.
Related
Examples
Experiments
Analyses