A *sampled-data* system contains both continuous-time and discrete-time parts — most often a continuous-time plant model together with a discrete-time control system running at a fixed rate. This page covers what is needed on top of ordinary [discrete-time modeling](/tutorials/discrete-time-modeling#discrete-time-modeling): the two operators that move signals between the domains, and how to think about them.

## Sample and hold {#Sample-and-hold}

The two domains describe signals on different time sets, and this difference is the origin of the complications described below:

* A **continuous-time** signal has a value at every instant of the simulated interval.

* A **discrete-time** signal has a value **only at the ticks of its associated clock**. Between ticks it is not "the previous value" — it is undefined. Asking what a clocked signal equals halfway between two ticks is not a meaningful question.

Two operators convert signals between the domains, and they are not symmetric.

[`Sampler`](../stdlib/DiscreteComponents/components/Sampler.md) **restricts** a continuous-time signal to the tick times of a clock. It discards information: the behavior of the signal between ticks is not represented in the result. Sampling corresponds to measuring the sampled signal when the clock ticks.

[`ZeroOrderHold`](../stdlib/DiscreteComponents/components/ZeroOrderHold.md) goes the other way. A discrete-time signal has no values between ticks, so producing a continuous-time signal from it requires **interpolation**: the sequence of samples is extended onto the continuous-time axis. Zero-order hold is the simplest such rule — keep the last sample constant until the next tick — which is what a digital-to-analog converter driven by a register physically does, and why it is the default. Other interpolations (linear, higher-order) are other choices of the same kind of rule.

Two consequences follow from the hold being an interpolation rather than a recovery:

* The continuous-time signal downstream of a hold is a *model* of what the hardware does between updates. If the real converter behaves differently, the model is wrong there in a way no choice of sample rate fixes.

* The phase lag of the loop is introduced by the hold, not by the sampler. Holding a value for one period delays it by half a period on average, which is why discretizing a controller reduces the phase margin.

## Connecting across the boundary {#Connecting-across-the-boundary}

A *time-varying* continuous signal may not be connected directly to a clocked input — it has to pass through a `Sampler` first. This is why the example below routes its `Step` source through a sampler before the signal enters the discrete-time partition. A *time-invariant* signal such as a `Constant` may be connected directly, because it has the same value at every tick.

In the other direction, a clocked signal reaching a continuous-time component must pass through a `ZeroOrderHold`.

## Troubleshooting {#Troubleshooting}

|                                                         Symptom |                                                                                                                                                                 Cause and fix |
| ---------------------------------------------------------------:| -----------------------------------------------------------------------------------------------------------------------------------------------------------------------------:|
| `Attempted to combine clocked value with continuous-time value` | A continuous-time signal reached a clocked equation, or a clocked signal reached a continuous-time one. Insert a `Sampler` or a `ZeroOrderHold` in the appropriate direction. |

For clock errors that do not involve the continuous-time domain, see [Troubleshooting clock errors](/tutorials/discrete-time-modeling#discrete-time-troubleshooting).

## Reading results across the boundary {#Reading-results-across-the-boundary}

The idioms for plotting and indexing clocked variables are the same as for a purely discrete-time model — see [Reading results](/tutorials/discrete-time-modeling#discrete-time-reading-results).

A `ZeroOrderHold` output is stored on the clock partition of the signal connected to its input, so it is read like any other clocked variable: in a model with `connect(controller.y, zoh.u)`, `sol[model.zoh.y]` and `sol(t; idxs = model.zoh.y)` return the held trace and agree with `model.controller.y`. The same holds for any variable defined by a hold.

## Linearization of sampled-data systems {#Linearization-of-sampled-data-systems}

Linearization of discrete-time and sampled-data systems can be performed using [frequency-response analysis (FRA)](../analyses/frequency_response.md) in DyadControlSystems. FRA amounts to simulating a system with wide-spectrum inputs and computing the linear small-signal transfer function using techniques from the field of system identification.

FRA is used here because forward-mode automatic differentiation cannot currently propagate through a clocked update, so the analytic linearization available for purely continuous models does not apply to a partition that contains discrete-time logic. FRA is not subject to this limitation because it uses simulation data only.

## A complete example {#A-complete-example}

Below, we model a simple continuous first-order system called `plant` that is controlled using a discrete-time controller. The reference signal is filtered using a discrete-time exponential filter before it is passed to the controller. We use a `Sampler` driven by a `PeriodicClock` to sample the plant output, and `ZeroOrderHold` to convert the discrete controller output back to continuous time.
Download as a Dyad projectclocks.zipOpen in Dyad Studio›

```dyad
"""
A simple sampled-data control system with a continuous-time first-order plant
and a discrete-time proportional controller with reference filtering.
"""
example component SampledDataDemo
  "Continuous-time first-order plant"
  plant = BlockComponents.Continuous.FirstOrder(k = 1, T = 1) {^plant}
  "Reference step"
  ref = BlockComponents.Sources.Step(height = 1, start_time = 5) {^ref}
  "Sample the reference before it enters the discrete-time partition"
  ref_sampler = DiscreteComponents.Sampler() {^ref_sampler}
  "Sample the plant output"
  sampler = DiscreteComponents.Sampler() {^sampler}
  clock = DiscreteComponents.PeriodicClock(dt = 0.5) {^clock}
  "Discrete-time exponential reference filter"
  filt = DiscreteComponents.ExponentialFilter(a = 0.393) {^filt}
  "Control error: filtered reference minus sampled plant output"
  err = BlockComponents.Math.Add(k2 = -1) {^err}
  "Proportional controller (discrete-time)"
  gain = BlockComponents.Math.Gain(k = 1) {^gain}
  "Hold controller output for the plant"
  zoh = DiscreteComponents.ZeroOrderHold() {^zoh}
relations
  initial plant.x = 1
  # Reference filtering. The continuous-time reference is sampled before it enters
  # the discrete-time partition that `filt` belongs to.
  connect(ref.y, ref_sampler.u) {^id8}
  connect(ref_sampler.y, filt.u) {^id15}
  # Error = filtered_ref - sampled_plant
  connect(filt.y, err.u1) {^id9}
  connect(sampler.y, err.u2, clock.y) {^id10}
  # Controller
  connect(err.y, gain.u) {^id11}
  # D/A conversion and plant
  connect(gain.y, zoh.u) {^id12}
  connect(zoh.y, plant.u) {^id13}
  # Feedback sampling
  connect(plant.y, sampler.u) {^id14}
metadata {
  "_links": {
    "plant": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": 40, "y1": 140, "x2": 240, "y2": 340, "rot": 0}
        },
        "tags": []
      }
    },
    "ref": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": -230, "y1": -220, "x2": -30, "y2": -20, "rot": 0}
        },
        "tags": []
      }
    },
    "ref_sampler": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": 40, "y1": -220, "x2": 240, "y2": -20, "rot": 0}
        },
        "tags": []
      }
    },
    "sampler": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": 300, "y1": 140, "x2": 500, "y2": 340, "rot": 0}
        },
        "tags": []
      }
    },
    "clock": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": 300, "y1": 380, "x2": 500, "y2": 580, "rot": 0}
        },
        "tags": []
      }
    },
    "filt": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": 300, "y1": -220, "x2": 500, "y2": -20, "rot": 0}
        },
        "tags": []
      }
    },
    "err": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": 570, "y1": 80, "x2": 770, "y2": 280, "rot": 0}
        },
        "tags": []
      }
    },
    "gain": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": 830, "y1": 80, "x2": 1030, "y2": 280, "rot": 0}
        },
        "tags": []
      }
    },
    "zoh": {
      "Dyad": {
        "placement": {
          "diagram": {"iconName": "default", "x1": 1078, "y1": 80, "x2": 1278, "y2": 280, "rot": 0}
        },
        "tags": []
      }
    },
    "id8": {"Dyad": {"edges": [{"S": 1, "M": [], "E": 2}], "renderStyle": "standard"}},
    "id9": {
      "Dyad": {
        "edges": [{"S": 1, "M": [{"x": 540, "y": -120}, {"x": 540, "y": 120}], "E": 2}],
        "renderStyle": "standard"
      }
    },
    "id10": {"Dyad": {"edges": [{"S": 1, "M": [], "E": 2}], "renderStyle": "standard"}},
    "id11": {"Dyad": {"edges": [{"S": 1, "M": [], "E": 2}], "renderStyle": "standard"}},
    "id12": {"Dyad": {"edges": [{"S": 1, "M": [], "E": 2}], "renderStyle": "standard"}},
    "id13": {
      "Dyad": {
        "edges": [
          {
            "S": 1,
            "M": [
              {"x": 1300, "y": 180},
              {"x": 1300, "y": 650},
              {"x": 0, "y": 650},
              {"x": 0, "y": 240}
            ],
            "E": 2
          }
        ],
        "renderStyle": "standard"
      }
    },
    "id14": {"Dyad": {"edges": [{"S": 1, "M": [], "E": 2}], "renderStyle": "standard"}},
    "id15": {"Dyad": {"edges": [{"S": 1, "M": [], "E": 2}], "renderStyle": "standard"}}
  }
}
end

analysis SampledDataDemoAnalysis
  extends TransientAnalysis(stop = 15.0)
  model = SampledDataDemo()
end
```

We can now simulate the system:

```julia
using Plots
plot(SampledDataDemoAnalysis())
```

![](qjyvhtu.svg)

## Known limitations {#Known-limitations}

Beyond the [discrete-time limitations](/tutorials/discrete-time-modeling#discrete-time-limitations), these apply to sampled-data models specifically.

* **No automatic differentiation through a clocked partition.** Forward-mode AD does not propagate through the discrete-time update, so the analytic linearization available for purely continuous-time models does not apply; use FRA instead.

* **FMU export rejects models containing events**, which includes clocked models.

* **A model containing a continuous-time partition cannot be compiled to a standalone program.** See [Code Generation and Deployment](/tutorials/discrete-code-generation#discrete-code-generation).

## See also {#See-also}

* [Discrete-Time Modeling](/tutorials/discrete-time-modeling#discrete-time-modeling) — clocks, the synchronous programming model, difference equations and multi-rate systems

* [Measurement Noise and Corruption](/tutorials/noise#noise-tutorial) — sensor imperfections, quantization and AD effects

* [DC Motor with PI Controller](/tutorials/dc-motor-pi#dc-motor-pi) — a continuous-time model converted to sampled-data control, then to cascade control

* [On-Off Controller](/tutorials/onoff-controller#onoff-controller) — a relay controller with hysteresis

* [Sliding-Mode Control](/tutorials/sliding-mode-control#sliding-mode-control) — a discrete-time super-twisting controller

* [Discretizing Continuous-Time Linear Systems](/tutorials/discretizing-linear-systems#discretizing-linear-systems) — `c2d` and the choice of discretization method

* [Frequency-response analysis](../analyses/frequency_response.md) — linearizing a sampled-data system

* [ControlSystems.jl: Analysis of sampled-data systems](https://juliacontrol.github.io/ControlSystems.jl/dev/examples/zoh/) — how the hold interacts with continuous-time frequency-domain analysis

* [DyadControlSystems](https://help.juliahub.com/dyad/DyadControlSystems.jl/dev/) — controller design, MPC and state estimation