# `Analog.Basic.Ground` {#Analog.Basic.Ground}

Ideal electrical ground connection, providing a zero-voltage reference.

This component establishes a reference potential in an electrical circuit. It defines a node where the voltage is explicitly set to zero. Any part of a circuit connected to this ground component will share this zero-voltage reference. The fundamental relationship defining this component is:

$$g.v = 0$$

## Usage {#Usage}

`ElectricalComponents.Analog.Basic.Ground()`

## Connectors {#Connectors}

* `g` - This connector represents an electrical pin with voltage and current as the potential and flow variables, respectively. ([`Pin`](/stdlib/Dyad/connectors/Pin#Pin))

## Behavior {#Behavior}

$$ \begin{align}
\mathtt{g.v}\left( t \right) &= 0
\end{align}
$$

## Source {#Source}

````dyad
"""
Ideal electrical ground connection, providing a zero-voltage reference.

This component establishes a reference potential in an electrical circuit. It
defines a node where the voltage is explicitly set to zero. Any part of a
circuit connected to this ground component will share this zero-voltage
reference. The fundamental relationship defining this component is:

```math
g.v = 0
```
"""
component Ground
  "Electrical connection pin."
  g = Pin() {
    "Dyad": {
      "placement": {"icon": {"iconName": "pos", "x1": 450, "y1": -50, "x2": 550, "y2": 50}}
    }
  }
relations
  g.v = 0
metadata {
  "Dyad": {
    "labels": [{"label": "$(instance)", "x": 500, "y": 1005, "rot": 0}],
    "icons": {"default": "dyad://ElectricalComponents/Ground.svg"}
  }
}
end
````

````dyad
"""
Ideal electrical ground connection, providing a zero-voltage reference.

This component establishes a reference potential in an electrical circuit. It
defines a node where the voltage is explicitly set to zero. Any part of a
circuit connected to this ground component will share this zero-voltage
reference. The fundamental relationship defining this component is:

```math
g.v = 0
```
"""
component Ground
  "Electrical connection pin."
  g = Pin() {
    "Dyad": {
      "placement": {"icon": {"iconName": "pos", "x1": 450, "y1": -50, "x2": 550, "y2": 50}}
    }
  }
relations
  g.v = 0
metadata {
  "Dyad": {
    "labels": [{"label": "$(instance)", "x": 500, "y": 1005, "rot": 0}],
    "icons": {"default": "dyad://ElectricalComponents/Ground.svg"}
  }
}
end
````

## Test Cases {#Test-Cases}

No test cases defined.

## Related {#Related}

* Examples

* Experiments

* Analyses

* Tests
  * [`AmplifierWithOpAmpDetailed`](Analog.Basic.Ground.md)

  * [`CCC`](Analog.Basic.Ground.md)

  * [`CCV`](Analog.Basic.Ground.md)

  * [`DiodeBreakdown`](Analog.Basic.Ground.md)

  * [`DiodeForward`](Analog.Basic.Ground.md)

  * [`DiodeHeating`](Analog.Basic.Ground.md)

  * [`DiodeTemperature`](Analog.Basic.Ground.md)

  * [`DiodeTest`](Analog.Basic.Ground.md)

  * [`Gyrator`](Analog.Basic.Ground.md)

  * [`MTransformer`](Analog.Basic.Ground.md)

  * [`MultiSensor`](Analog.Basic.Ground.md)

  * [`NMOSOperatingPoint`](Analog.Basic.Ground.md)

  * [`NMOSTest`](Analog.Basic.Ground.md)

  * [`NPNOperatingPoint`](Analog.Basic.Ground.md)

  * [`NPNSwitching`](Analog.Basic.Ground.md)

  * [`NPNTest`](Analog.Basic.Ground.md)

  * [`PMOSOperatingPoint`](Analog.Basic.Ground.md)

  * [`PMOSTest`](Analog.Basic.Ground.md)

  * [`PNPOperatingPoint`](Analog.Basic.Ground.md)

  * [`PNPTest`](Analog.Basic.Ground.md)

  * [`Potentiometer`](Analog.Basic.Ground.md)

  * [`RotationalEMF`](Analog.Basic.Ground.md)

  * [`SaturatingInductor`](Analog.Basic.Ground.md)

  * [`Sensors`](Analog.Basic.Ground.md)

  * [`TranslationalEMF`](Analog.Basic.Ground.md)

  * [`VCC`](Analog.Basic.Ground.md)

  * [`VCV`](Analog.Basic.Ground.md)

  * [`VariableCapacitor`](Analog.Basic.Ground.md)

  * [`VariableConductor`](Analog.Basic.Ground.md)

  * [`VariableInductor`](Analog.Basic.Ground.md)